Quick Service for Full HMI Parts Replacement
Home / All / Exor UniOP / UniOP Exor HMI /

UniOP ER-25T-0045 HMI Touch Screen Front Overlay

UniOP ER-25T-0045 HMI Touch Screen Front Overlay

UniOP ER-25T-0045 HMI Touch Screen Front Overlay
UniOP ER-25T-0045 HMI Touch Screen Front OverlayUniOP ER-25T-0045 HMI Touch Screen Front OverlayUniOP ER-25T-0045 HMI Touch Screen Front Overlay
CategoriesUniOP Exor HMI
BrandVICPAS
ModelER-25T-0045
BrandUniOP
Warranty365 Days
Product LineUniOP series
SupplyER-25T-0045 Protective Film Touch Screen Repair
Size9.6 inch
FOB portGuangzhou, Shenzhen, Hongkong
Terms of PaymentWestern Union, MoneyGram, T/T, Paypal, PayPal, Credit Card
Update TimeDec 23,2024
Detail Information

UniOP series HMI ER-25T-0045 Touch Screen Panel Front Overlay Repair


UniOP series HMI ER-25T-0045 Touchscreen Front Overlay Repair Kit

ER-25T-0045 Touch Screen Protective Film IHM Highlights
• 9.6” diagonal graphic monochrome LCD display
• Available in TFT color, and monochrome
• VGA (640x480 pixels) resolution
• Shows up to 30 rows, 80 characters of information
• Resistive ER-25T-0045 touch screen
• Connection to industrial bus systems and Ethernet (requires optional plug-in modules)
• Compatible with HMIcontrol and local I/O subsystems
• Large memory size (8 MB Flash) on removable media
• IP65 front panel protection
• Programmable with UniOP Designer version 5.08


The ER-25T-0045 HMI Panel Glass Front Overlay Terminal are state-of-the-art HMI devices with a touch screen interface and a 10.4” graphic display (9.6” for monochrome version). The novel aluminum bezel offers a rugged and convenient flat design and an appealing look.





Specifications:

The table below describes the parameters of the ER-25T-0045 UniOP Touchscreen Overlay.

Part Number: ER-25T-0045
Display Type: Monochrome LCD
Resolution: 640x480 pixel
Backlight: CCFL
Warranty: 365 Days
Input Power: 24VDC (+10%, -15%)
Operating Temperature: 0 to 45 °C
Display Size: 9.6 in
Touch screen: Resistive


Related UniOP Series Part No. :

UniOP eTOP Description Inventory status
ECT-VGA-0045 Exor UniOP Touch Screen Monitor Overlay Repair In Stock
EK-41 6ZA925-7 Membrane Keyboard Keypad UniOP Replacement Available Now
EK-42 6ZA987-7 UniOP Membrane Keypad Switch Repair Part In Stock
EL-25T-0042 Exor UniOP Touch Screen Panel Protective Film In Stock
ER-25T-0045 UniOP HMI Touch Screen Front Overlay Replacement In Stock
ERT-16-0042 HMI Panel Glass Overlay Exor UniOP Repair Available Now
ERT-16-0045 Exor UniOP Front Overlay Touch Panel Glass In Stock
ERT-16-2945 UniOP Touch Screen Protective Film Repair Kit Available Now
ETT-VGA-0045 UniOP Touch Digitizer Protective Film Replacement In Stock
ETT-VGA-6545 HMI Panel Glass Overlay Replacement Repair Available Now
TECT-VGA-0345 Exor UniOP HMI Panel Glass Front Overlay In Stock
Exor UniOP HMI Description Inventory status


Exor UniOP HMI Manuals PDF Download:

  • UniOP ETT-VGA User Manual
  • UniOP User's Manual
  • UniOP Universal Operator Panels Installation Guide
  • UniOP Touch & Controls PDF
  • UniOP Manual
  • UniOP Installation Guide

  • FAQ:

    Question: How to cleaning ER-25T-0045 Touch Panel Glass Overlay IHM faceplates?

    Answer: The equipment must be cleaned only with a soft cloth and neutral soap product. Do not use solvents.


    Question: What is Exor UniOP ER-25T-0045 Touchscreen Calibration?

    Answer:

  • Standard calibration:
  • 1. Recall Configuration Mode
  • 2. Touch the CLEAR key on the ER-25T-0045 screen until a small round symbol will appear on the top right corner of the screen
  • 3. touch and hold the symbol until it will move to the low left corner of the ER-25T-0045 screen
  • 4. touch and hold the symbol until the indication to touch the ← key will be displayed on the screen
  • 5. touch and hold the key ← until the indication to touch the ↓ key will be displayed on the screen
  • 6. touch and hold the key ↓ until the indication to touch the Enter key will be displayed on the screen
  • 7. touch and hold the Enter key until the panel will switch to Operation Mode (if a valid project is loaded in the memory)
  • Emergency calibration.
  • The Emergency calibration procedure should be used in all cases when it would result not possible to go to calibration using the standard procedure.
  • 1. Switch of the unit
  • 2. turn on the unit
  • 3. tap in the middle of the touchscreen with a frequency of about one second until the operator panel will enter the Calibration Mode
  • 4. perform the standard calibration procedure.

  • Common misspellings: 

    R-25T-0045
    ER-5T-0045
    ER-25T-00454
    ER-257-0045
    ER-25TT-0045
    Review
    • Loading...
    Please send your message to us
    *Email
    Tel
    *Title
    *Content
    Upload
    • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
    Do you want to quickly know the product quotation you need?
    • Fast Quote
    • Worldwide Shipping
    • 12 Months Warranty
    • Customize Service
    subscription
    KEEP IN TOUCH
    Please send your message to us
    *Email
    Tel
    *Title
    *Content
    Upload
    • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
    CONTACT US
    QR code
    Mobile Web