Quick Service for Full HMI Parts Replacement
Home / All / for Siemens / Siemens ULTRAMAT/OXYMAT /

7MB2121-1CA00-0AA1 7MB2121-1CA10-0AA1 7MB2121-1CA20-1AA1 Membrane Keyboard

7MB2121-1CA00-0AA1 7MB2121-1CA10-0AA1 7MB2121-1CA20-1AA1 Membrane Keyboard

7MB2121-1CA00-0AA1 7MB2121-1CA10-0AA1 7MB2121-1CA20-1AA1 Membrane Keyboard
CategoriesSiemens ULTRAMAT/OXYMAT
BrandVICPAS
Model7MB2121-1CA00-0AA1 7MB2121-1CA10-0AA1 7MB2121-1CA20-1AA1
BrandSiemens
Size19 inch
Warranty365 Days
Product LineSeries 6
Shipping2-4 workdays
SupplyMembrane Switch
Part number7MB2121-1CA00-0AA1
Part number7MB2121-1CA10-0AA1 7MB2121-1CA20-1AA1
Terms of PaymentWestern Union, T/T, PayPal, Credit Card
Update TimeMar 15,2025
Detail Information

Siemens Ultramat 7MB2121-1CA00-0AA1 7MB2121-1CA10-0AA1 7MB2121-1CA20-1AA1 Terminal Keypad


Ultramat Siemens 7MB2121-1CA00-0AA1 7MB2121-1CA10-0AA1 7MB2121-1CA20-1AA1 Membrane Keypad Switch Replacement

The Siemens ULTRAMAT 6 7MB2121-1CA00-0AA1 7MB2121-1CA10-0AA1 7MB2121-1CA20-1AA1 Keyboard Membranes deliver precision control and robust performance for industrial gas analysis systems. These keypads, designed specifically for the ULTRAMAT 6 analyzers ensure seamless integration and reliable operation in demanding environments.

The industrial-grade 7MB2121-1CA00-0AA1 7MB2121-1CA10-0AA1 7MB2121-1CA20-1AA1 Membrane Keyboard Keypad ensures a long service life with excellent tactile feedback, even in demanding environments.


Features

● High-Quality Durability: Constructed with wear-resistant materials, the 7MB2121 series keypads are built to withstand harsh industrial conditions, including exposure to dust, moisture, and chemicals. Clear labeling and an ergonomic layout enhance operational efficiency and reduce errors.
● Intuitive Operation: The user-friendly interface simplifies navigation through analyzer menus, enabling quick parameter adjustments, calibration, and diagnostics. Responsive membrane switches provide reliable tactile feedback for accurate input in critical applications.
● Environmental Resilience: Engineered for Ultramat Siemens analyzers, these 7MB2121-1CA00-0AA1 7MB2121-1CA10-0AA1 7MB2121-1CA20-1AA1 Operator Panel Keypads maintain stable performance across extreme temperatures and mechanical stress, ideal for industries like power generation, chemical processing, and emissions monitoring.




Specifications:

The table below describes the parameters of the Siemens Ultramat 7MB2121-1CA00-0AA1 7MB2121-1CA10-0AA1 7MB2121-1CA20-1AA1 Switch Membrane HMI Parts.

Brand: Siemens
Operating Temperature: 5°C ~ 45°C
Position of Use: Front panel vertical
Warranty: 12-Month Warranty
Product Line: Series 6
Storage Temperature: -30°C~ 70°C
Permissible Humidity: < 90 %
Keypad Size: 19''


Related Siemens Ultramat HMI Part No. :

Siemens Ultramat HMI Description Inventory status
7MB2121-1AB20-0AA1 Siemens Ultramat Membrane Keypad Switch Repair In Stock
7MB2121-1AH00-0AA1 ULTRAMAT Siemens Operator Keyboard Replacement Available Now
7MB2121-1BD00-0AA1 Ultramat Siemens Keypad Keyboard Membrane Switch In Stock
7MB2121-1CA00-0AA1 Siemens Ultramat 6 Terminal Keypad Membrane Repair In Stock
7MB2121-1CA10-0AA1 Siemens ULTRAMAT Operator Keyboard Replacement Available Now
7MB2121-1CA20-1AA1 Siemens Ultramat Terminal Keypad Membrane Repair In Stock
7MB2121-1CB20-0AA1 Ultramat 6E Siemens Membrane Keypad Replacement Available Now
7MB2121-1CG00-0AA1 Siemens Ultramat Membrane Keyboard Keypad Repair Available Now
7MB2121-1ND00-0AA1 Siemens ULTRAMAT 6E Operator Panel Keypad Repair In Stock
7MB2123-0AE20-1AP1 Ultramat Siemens Switch Membrane Repair Replacement In Stock
7MB2123-0BE20-1BM1 Siemens Ultramat 6E Membrane Keyboard Replacement In Stock
7MB2123-0CA00-1CA1 Siemens ULTRAMAT Operator Panel Keypad HMI Repair Available Now
7MB2123-0CS00-0ND1 ULTRAMAT Siemens Membrane Keypad Overlay Repair In Stock
7MB2123-0CS00-1ND1 Ultramat Siemens Operator Keyboard Replacement Available Now
Siemens Ultramat HMI Description Inventory status


Siemens Ultramat HMI Manuals PDF Download:

  • ULTRAMAT 6 and OXYMAT 6 Analyzers for IR-absorbing gases and oxygen
  • Oxygen analyzer for standard applications OXYMAT 61

  • FAQ:

    Question: What to do if a Parameter Memory Test Failed error occurs?

    Answer: It may be caused by EEPROM containing incorrect or incomplete data in the working range.
    ✔ Execute RESET or switch the device off and on again. If the error message S1 appears again:
    ✔ Load user data (function 75)
    ✔ contact service department, Make sure you leave the device in operation to assist the fault diagnostics of the service staff!


    Question: What to do if microflow sensor faulty?

    Answer: The reason could be that half of the power grid has been destroyed.
    1. Replace the Sensor:
    · Order a Replacement: Contact the manufacturer or supplier to obtain a compatible replacement sensor. Ensure the new sensor matches the specifications of the original (e.g., flow range, electrical connections, and compatibility with your system).
    · Install the New Sensor: Follow the manufacturer’s installation instructions carefully to avoid damaging the new sensor.
    2. If the damage is recurring or you are unsure about the cause, contact the sensor manufacturer or a qualified technician for further assistance.


    Common misspellings: 

    7MB22121-1CA00-0AA1 7MB2121-1CA10-0AA1 7MB2121-1CA20-1AA1
    7MB2121-1CA00-0AA1 7MB221-1CA10-0AA1 7MB2121-1CA20-1AA1
    7MB2121-1CA00-0AA1 7MB2121-1CA10-0AA1 7MB2121-1CA21-1AA1
    7MB2121-1CA00-0AA1 7MB2121-1OCA10-0AA1 7MB2121-1CA20-1AA1
    7M82121-1CA00-0AA1 7MB2121-1CA10-0AA1 7MB2121-1CA20-1AA1
    Review
    • No review yet
    Please send your message to us
    *Email
    Tel
    *Title
    *Content
    Upload
    • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
    Do you want to quickly know the product quotation you need?
    • Fast Quote
    • Worldwide Shipping
    • 12 Months Warranty
    • Customize Service
    subscription
    KEEP IN TOUCH
    Please send your message to us
    *Email
    Tel
    *Title
    *Content
    Upload
    • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
    CONTACT US
    QR code
    Mobile Web