Delta DOP-B07S211 Membrane Keyboard Touch Panel Repair
Delta DOP-B Series DOP-B07S211 Touch Digitizer Operator Panel Keypad Replacement
Order each part separately is available
VICPAS supply Delta DOP-B Series DOP-B07S211 Keyboard Membrane and Touch Panel with 365 days warranty and support Urgent Worldwide Shipping.
Installation and Storage Conditions
The product should be kept in the shipping carton before installation. In order to retain the warranty coverage, the DOP-B07S211 Touch Screen Keypad Membrane HMI should be stored properly when it is not to be used for an extended period of time. Some storage suggestions are:
Store in a clean and dry location free from direct sunlight.
Store within an ambient temperature range of -20°C to +60°C (-4°F to 140°F).
Store within a relative humidity range of 10% to 90% and non-condensing.
Do not store the DOP-B07S211 Touch Digitizer Glass Switch Membrane HMI in a place subjected to corrosive gases and liquids.
Correctly packaged and placed on a solid and durable surface.
Do not mount the DOP-B07S211 Membrane Keyboard Touch Screen HMI adjacent to heat-radiating elements or in direct sunlight.
Do not mount the DOP-B07S211 Touch Screen Keypad Touch Panel HMI in a location subjected to corrosive gases, liquids, or airborne dust or metallic particles.
Do not mount the DOP-B07S211 Touchscreen Panel Membrane Keyboard HMI in a location where temperatures and humidity will exceed specification.
Do not mount the DOP-B07S211 Touch Digitizer Membrane Keypad HMI in a location where vibration and shock will exceed specification.
Do not mount the DOP-B07S211 Membrane Switch Touchscreen HMI in a location where it will be subjected to high levels of electromagnetic radiation.
Specifications:
The table below describes the parameters of the Delta DOP-B DOP-B07S211 Touch Screen Monitor Membrane Keyboard Keypad HMI Parts.
Backlight: | LED Back Light |
Display Resolution: | 800 x 480 pixels |
Cooling Method: | Natural air circulation |
Product Line: | Delta DOP-B |
Touch Size: | 7" |
Brand: | Delta |
Display Type: | TFT LCD |
Operation Temperature: | 0 °C ~ 50 °C |
Storage Temperature: | -20 °C ~ +60 °C |
Warranty: | 365 Days |
Related Delta DOP-B Series HMI Part No. :
Delta DOP-B HMI | Description | Inventory status |
DOP-B07E411 | Delta DOP-B Series Touch Screen Protective Film Replacement | In Stock |
DOP-B07E415 | Delta DOP-B Series Touch Panel Protective Film Repair | Available Now |
DOP-B07E515 | Delta DOP-B Series Touchscreen Protective Film Repair | In Stock |
DOP-B07PS415 | Delta DOP-B Series HMI Touch Screen Glass Protective Film | Available Now |
DOP-B07PS515 | Delta DOP-B Series Touch Screen Panel Front Overlay Repair | In Stock |
DOP-B07S200 | Delta DOP-B Series HMI Touch Membrane Replacement | In Stock |
DOP-B07S201 | Delta DOP-B Series Touch Glass Replacement Repair | In Stock |
DOP-B07S211 | Delta DOP-B Series Touch Digitizer Glass Membrane Keypad | Available Now |
DOP-B07S401K | Delta DOP-B Series HMI Panel Glass Replacement | Available Now |
DOP-B07S410 | Delta DOP-B Series Touch Screen Monitor Front Overlay | In Stock |
DOP-B07S411 | Delta DOP-B Series MMI Touch Screen Front Overlay Replacement | In Stock |
DOP-B07S411K | Delta DOP-B Series HMI Touch Screen Terminal Keypad | In Stock |
DOP-B07S415 | Delta DOP-B Series Front Overlay Touch Screen Panel Repair | In Stock |
Delta DOP-B Series | Description | Inventory status |
Delta DOP-B Series HMI Manuals PDF Download:
FAQ:
Question: How do I fix the problem if the Delta DOP-B07S211 Keyboard Membrane Touch Screen Human Machine Interface (HMI) is unable to connect to the computer through the connection cable?
Answer:
Generally, the connection between the DOP-B07S211 Touch Panel Membrane Keypad Switch HMI and computer is established through a USB type B connection wire for uploading and downloading. The user has to configure the HMI in accordance with different computer operating systems. Go to Options > Configuration > Others > USB Download
1. For Windows XP, the upload/download mode should be set to 0 (normal mode).
2. For Windows 7, 8, or 10, the upload/download mode should be set to 1 (disk mode)
3. If the USB permission is restricted by the IT department, please set to mode 2 (CDC mode). If the connection between the DOP-B07S211 Touch Digitizer Keypad Membrane HMI and computer is not established before the beginning of the project, new settings won't be uploaded or downloaded. In this case, the user has to set up the system by pressing the system menu from the back of the DOP-B07S211 Operator Panel Keypad Touchscreen Panel HMI.
Please follow the steps below.
1. Press the system menu button on the back of the DOP-B07S211 Touch Screen Monitor Switch Membrane HMI for 2 to 3 seconds. When the button is pressed, the buzzer will respond with a “beep” as notification (this is normal, not a warning).
2. Upon entering the DOP-B07S211 Operator Keyboard Touch Screen Panel Glass HMI system menu, press the screen to enter System Setting > Misc. > USBCommMode and set the mode as 0 or 1 or 2.
3. After setting up, press the top right corner to go back to the DOP-B07S211 Touch Panel Touch Screen Keypad HMI project screen.
Common misspellings:
DOP-B0S211OP-B07S211
DOP-B70S211
DOP-B07SZ11
DOPP-B07S211
- Loading...
- Tel
- *Title
- *Content
- Fast Quote
- Worldwide Shipping
- 12 Months Warranty
- Customize Service
- Tel
- *Title
- *Content