ESA Text HMI VT4202SFF00 Membrane Keypad Keyboard
ESA TEXT HMI VT420 VT4202SFF00 Membrane Keyboard Replacement
VT420 25F000 ESA VIDEO TERMINAL (VT) is a device that allows the user to control orsimply monitor a productive process. It can send commands using configuredby the user; it can send data determining the process on hand andcan display information deriving from the productive process. The informationcan be in the form of an Alarm, an Information (Info-) Message or inbinary data format.
VICPAS supply ESA TEXT HMI VT420 membrane switch with 6 months warranty and support Urgent Worldwide Shipping.
Specifications:
The table below describes the parameters of the ESA VT4202SFF00 HMI Parts.
Brand: | ESA |
Display Type: | Graphic LCD 16 colors STN |
Resolution: | 320x240 |
Warranty: | 6-Months Warranty |
Product Line: | VT TEXT |
Display Type: | TEXT LCD |
Display area size: | 4.55x3.43 |
Columns by Rows: | Depending on used Font |
Size: | 5.7" |
Part Number: | VT4202SFF00 |
Related ESA VT420 Part No. :
ESA VT420 | Description | Inventory status |
VT420L1SF000 | ESA Text HMI VT420L1SF000 Membrane Keypad Repair Replacement | In Stock |
VT42025F000 | ESA Text HMI VT420 VT42025F000 Membrane Keyboard Repair | In Stock |
VT4201SF000 | ESA Text HMI VT420 VT4201SF000 Membrane Switch Replacement | In Stock |
VT4202SF000 | ESA Text HMI VT420 VT4202SF000 Membrane Keypad Replacement | In Stock |
VT4202SFF00 | ESA Text HMI VT420 VT4202SFF00 Terminal Keypad Repair Part | In Stock |
ESA VT TEXT | Description | Inventory status |
ESA VT420 Operator Panel HMI Manuals PDF Download:
FAQ:
Question: How to adjust the contrast on the ESA VT420 Display?
Answer:To improve the quality of the representation on the display it may be necessaryto adjust its contrast. This can be done by rotating the trimmer (C) atthe back of the VT ; turn it (using a small screwdriveror a trimmer tool) in one direction and, if the display quality worsens,turn it the other way.
Question: What is the VT420 Termination of CAN line?
Answer:The VT in question integratesthe termination resistances of the serial line (typically 120 ohms)which can be inserted by means of a jumper (preset on 1-2, line not terminated).To activate the termination:
• Make sure the device is not connected to the power supply.
• Remove the cover.
• Identify the jumper unit J2.
• Position the jumper between pins 2 and 3 (line terminated).
• Replace the back cover.
• Reconnect the power supply.