2711P-K12C6D7 Membrane Keypad Keyboard Repair
2711P-K12C6D7 Panelview Plus 1250 Terminals Membrane Keypad, Protection Board, Label, LCD Display Screen, Plastic Cover, Gasket Repair Replacement
Order each part separately is available
The 2711P-K12C6D7 display system comes with the FAT 16, FAT32, and 64 Megabytes versions. The 2711P-K12C6D7 display comes in an open architecture and also supports the .Net Compact Framework, though it is not installed at the factory. The approximate dimensions of the 2711P-K12C6D7 terminal are 11.12 x 16.36 x 2.18 inches and weigh 7.6 lbs. or 3.4 kg. The enclosure rating of this terminal is NEMA Type 12, 13, 4X, IP54, and IP65.
The keypad of the 2711P-K12C6D7 PanelView Terminal has an actuation rating of 1-million-press. Further, there are 40 function keys, navigation keys, and numeric keys strategically arranged around the LCD. The 2711P-K12C6D7 is an Allen-Bradley PanelView 1250 color display computer that runs the Windows CE 4.1 operating system. The application software for the 2711P-K12C6D7 is the FactoryTalk View ME Station Software, Version 3.20.
For communications, the interfaces that come with 2711P-K12C6D7 include 1 10/100 megabytes per seconds Ethernet port, 1 D89 RS-232 interface, and it also supports the ControlNet, DH+™, DH-485, Remote I/O, and DeviceNet networks as optional add-on communication modules. For the supported interfaces, the 2711P-K12C6D7 supports 1 CF Type 1 CompactFlash card on the SD slot, the 2 USB-A, V1.1 USB ports, and the I PCI, 3.3/5 Volts with a 32-bit PCI.
The base unit terminal has a built-in Ethernet and RS-232 communication ports and the communication module known as the 2711P-RN20 provides an additional Ethernet port, a Standard Communication (Ethernet and RS-232) port, and scheduled and unscheduled communication capabilities.
Specifications:
The table below describes the parameters of the Panelview Plus 1250 2711P-K12C6D7 terminals Parts.
Part Number: | 2711P-K12C6D7 |
Display Size: | 12.1 inches |
Display Color: | Amber |
Warranty: | 180 days Warranty |
Product Line: | Panelview Plus 1250 |
Input Type: | Keypad |
Mounting Position: | vertical |
Communication: | Ethernet and RS-232 |
Communication: | ControlNet |
Software: | FactoryTalk |
Related Allen Bradley Panelview Plus 1250 Terminals Part No. :
PanelView Plus 1250 HMI | Description | Inventory status |
2711P-K12C6D1 | Allen Bradley Panel Plus 1250 Membrane Keypad LCD Screen Plastic Cover Body | In Stock |
2711P-K12C6D2 | Allen Bradley Panel View Plus 1250 Keypad LCD Display Enclosure Repalcement | Available Now |
2711P-K12C6D6 | PanelView Plus 1250 Membrane Switch LCD Display Screen Plastic Cover Body | In Stock |
2711P-K12C6D7 | PanelView Plus 1250 Membrane Keyboard Keypad LCD Display Screen HMI Case | In Stock |
2711P-K12C15A1 | PanelView Plus 1250 Membrane Keypad Switch LCD Display Housing Repair Kit | In Stock |
2711P-K12C15A2 | Allen Bradley PanelView Plus 1250 Operator Panel Keypad LCD Screen HMI Case | In Stock |
2711P-K12C15A6 | PanelView Plus 1250 Operator Keyboard LCD Display Housing Replacement | Available Now |
2711P-K12C15A7 | Allen Bradley Panel View Plus 1250 Keyboard Membrane LCD Screen Plastic Shell | In Stock |
2711P-K12C15B1 | Allen Bradley Panel View Plus 1250 Keypad Membrane LCD Display Housing | Available Now |
2711P-K12C15B2 | PanelView Plus 1250 Switch Membrane Enclosure LCD Display Panel Replacement | In Stock |
2711P-K12C15D1 | PanelView Plus 1250 Plastic Shell LCD Display Screen Keypad Repair Kit | In Stock |
2711P-K12C15D2 | Allen Bradley PanelView Plus 1250 Membrane Keyboard LCD Display Housing | In Stock |
2711P-K12C15D6 | PanelView Plus 1250 Membrane Keyboard Keypad LCD Screen HMI Case Repair | Available Now |
2711P-K12C15D7 | Allen Bradley Panel View Plus 1250 Operator Panel Keypad LCD Display Enclosure | In Stock |
AB PanelView Plus 1250 | Description | Inventory status |
AB Panelview Plus 1250 Manuals PDF Download:
FAQ:
Question: How to change the Decimal Separator for Numeric Formats?
Answer: You can change the decimal separator used in numerics for the current language. The default decimal separator is a period.
1. Select Terminal Settings>Time/Date/Regional Settings>Regional Settings>Numeric Format.
The field shows the default decimal separator. The field will accept a separator up to three characters.
2. Enter up to three characters for the new separator.
3. Click OK.
Question: What steps need to be connectted the terminal 2711P-K12C6D7 to AC power?
Answer:
1. Verify that the terminal is not connected to a power source.2. Secure the AC power wires to the terminal block.
Follow the markings on terminal blocks and terminal for proper connections.
3. Secure the protective earth/ground wire to the marked position of the power input terminal block.
4. On the 700 to 1500 devices, also secure the functional earth/ground wire to the functional earth terminal screw on the back of the display to ground bus.
5. Apply AC power to the terminal.
Question: How to replace a 2711P-K12C6D7 communication module?
Answer:
1. Disconnect power from the terminal.
2. Disconnect the communication cables from the module.
3. Loosen the three screws that secure the communication module to the terminal.
4. Carefully lift the communication module away from the terminal and set aside.
5. Install the new communication module.
Question: How to delete Log Files from Terminal 2711P-K12C6D7?
Answer:
You can delete log files, alarm history files, and alarm status files from the System Default location on the terminal.
1. Select Terminal Settings>File Management>Delete Files>Delete Log Files.
You are asked to confirm the deletion of the files.
Do you want to delete all of the FactoryTalk View ME Station Log Files?
2. Select Yes or No.Log files not located in the System Default location will not be deleted.
Common misspellings:
271P-K12C6D7
2711P-K1C6D7
2711P-K12C6D
2171P-K12C6D7
2711PK-12C6D7
2711P-K21C6D7
2711PP-K12C6D7
2711P--K12C6D7
2711P-K12C6DD7
- Loading...
- Tel
- *Title
- *Content
- Fast Quote
- Worldwide Shipping
- 12 Months Warranty
- Customize Service
- Tel
- *Title
- *Content