Quick Service for Full HMI Parts Replacement
Home / All / Allen Bradley / Panelview Plus 1000 /

2711P-K10C15A1 Membrane Keypad Keyboard Repair

2711P-K10C15A1 Membrane Keypad Keyboard Repair

2711P-K10C15A1 Membrane Keypad Keyboard Repair
2711P-K10C15A1 Membrane Keypad Keyboard Repair2711P-K10C15A1 Membrane Keypad Keyboard Repair2711P-K10C15A1 Membrane Keypad Keyboard Repair2711P-K10C15A1 Membrane Keypad Keyboard Repair2711P-K10C15A1 Membrane Keypad Keyboard Repair
CategoriesPanelview Plus 1000
BrandVICPAS
Model2711P-K10C15A1
Warranty180 Days
BrandRockwell Automation Allen Bradley
Product LinePanelview Plus 1000
SupplyPanelview Plus 1000 Terminals Membrane keypad
Size10.4 inch
model2711P-K10C15A1
PartsKeypad Switch Repair LCD Display
Terms of PaymentWestern Union, MoneyGram, T/T, Paypal, PayPal, Credit Card
Download
Update TimeNov 22,2024
Detail Information

2711P-K10C15A1 Panelview Plus 1000 Terminals Membrane Keypad LCD Display Plastic Case Repair

Order each part separately is available

2711P-K10C15A1 Panelview Plus 1000 Terminals Membrane Keypad, Protection Board, Label, LCD Display, Enclosure, Gasket and Mounting Clips Repair Replacement


The Panelview Plus 1000 2711P-K10C15A1 has a 10.4 in. Color Display screen. This Panelview enables the user to connect using FactoryTalk View Machine Edition software and a ControlNet communication port with a 1747-KFC15A communication cable(s). The user is able to control the operator terminal using the Keypad/Touchscreen to input information and data. This unit is powered using 18-32 VDC power. This Panelview Plus has the following internal memory: 256 MB. This unit has an internal backlight replacement part number of 2711P-RL10C.


The 2711P-K10C15A1 keypad is designed for finger or gloved finger operation. The touch screen may be operated with a finger, gloved finger, or plastic stylus device with a minimum tip radius of 1.3 mm (0.051 in.) to prevent damage to the touch screen. Using any other object or tool may damage the touch screen or keypad.


The ControlNet terminals support symbolic CIP addressing when communicating with a ControlLogix system. Every terminal offers a Network Access port for local access to the ControlNet network. Application files are easily downloaded or uploaded using PanelBuilder32 over the ControlNet link, directly via the on-board RS-232 printer port, or with a PC memory card.


VICPAS supply panelview Plus 2711P-K10C15A1 membrane keyboard switch, Protection Board, Label, HMI Case, LCD Display Screen, Mounting Clips and Gasket. All of them with VICPAS 180-day warranty and support Urgent Worldwide Shipping.





Specifications:

The table below describes the parameters of the Panelview Plus 1000 2711P-K10C15A1 terminals Parts.

Part Number: 2711P-K10C15A1
Display Size: 10.4 inches
Display Color: Amber
Warranty: 180 days Warranty
Product Line: Panelview Plus 1000
Input Type: Keypad
Mounting Position: vertical
Communication: Ethernet and RS-232
Language: Worldwide
Software: Talk View Machine Edition


Related Allen Bradley Panelview Plus 1000 Terminals Part No. :

PanelView Plus 1000 HMI Description Inventory status
2711P-K10C6D1 PanelView Plus 1000 Membrane Keyboard LCD Display Plastic Shell Repair Kit In Stock
2711P-K10C6D2 PanelView Plus 1000 Membrane Keyboard Keypad LCD Display Panel Enclosure Available Now
2711P-K10C6D6 Allen Bradley Panel Plus 1000 Membrane Keypad LCD Screen Plastic Cover Body In Stock
2711P-K10C6D7 Allen Bradley Panel View Plus 1000 Keypad LCD Display Enclosure Repalcement In Stock
2711P-K10C15A1 PanelView Plus 1000 Membrane Switch LCD Display Screen Plastic Cover Body In Stock
2711P-K10C15A2 PanelView Plus 1000 Membrane Keyboard Keypad LCD Display Screen HMI Case In Stock
2711P-K10C15A6 PanelView Plus 1000 Membrane Keypad Switch LCD Display Housing Repair Kit Available Now
2711P-K10C15A7 Allen Bradley PanelView Plus 1000 Operator Panel Keypad LCD Screen HMI Case In Stock
2711P-K10C15B1 PanelView Plus 1000 Operator Keyboard LCD Display Housing Replacement Available Now
2711P-K10C15B2 Allen Bradley Panel View Plus 1000 Keyboard Membrane LCD Screen Plastic Shell In Stock
2711P-K10C15D1 Allen Bradley Panel View Plus 1000 Keypad Membrane LCD Display Housing In Stock
2711P-K10C15D2 PanelView Plus 1000 Switch Membrane Enclosure LCD Display Panel Replacement In Stock
2711P-K10C15D6 PanelView Plus 1000 Plastic Shell LCD Display Screen Keypad Repair Kit Available Now
2711P-K10C15D7 Allen Bradley PanelView Plus 1000 Membrane Keyboard LCD Display Housing In Stock
AB PanelView Plus 1000 Description Inventory status

AB Panelview Plus 1000 Manuals PDF Download:

  • 2711P-K10C15A1 Terminals Manuals
  • Allen Bradley Panelview Plus 1000 Terminals Manuals
  • PanelView Plus 700 to 1500 and PanelView Plus Compact 1000 Terminals and Display Modules
  • Panelview Plus 1000 battery replacement Installation Instructions


  • FAQ:

    Question: How to access panelview plus 1000 configuration mode?

    Answer: Your PanelView Plus 1000 device has onboard software, FactoryTalk View ME Station, to perform and configure terminal operations. When you reset or start the terminal, you automatically enter Configuration mode, unless your.MER application is automatically set to run on startup.

    To access Configuration mode from a running application, press the Goto Configuration Mode button. This button is added to the application screen in FactoryTalk View Studio. The application stops running but is still loaded


    IMPORTANT To access Configuration mode from a running application, you must add a Goto Configuration Mode button to an application screen.

    On PanelView Plus 1000 Terminals HMI device, you can enter Configuration mode from the Start menu or the desktop.

     Select Start>Programs>Rockwell Software>FactoryTalk View>FactoryTalkView ME Station.
     Select the FactoryTalk View ME Station icon on the desktop.

    How to access panel view plus 1000 configuration mode?

    • Load Application (F1):Opens another screen where you can select an application to load. Once loaded, the application name will appear under Current Application.

    • Run Application (F2): Runs the .mer application displayed under Current Application. An application must be loaded before you can run it. Application Settings (F3) Opens a menu of application-specific configuration settings. Terminal Settings (F4) Opens a menu of options to configure non-application, specific terminal settings for the PanelView Plus device.

    • Delete Log Files Before Running (F5): Toggles between Yes and No. If you select Yes, all data log files, alarm history and alarm status files will be deleted before the application is run. If you select No, log files are not deleted first.

    • Reset (F7): Resets the terminal. The action that occurs on startup for PanelView Plus CE devices depends on whether you defined shortcut paths in the Windows Startup folder. On other PanelView Plus devices, the action on startup depends on configured startup options.
    • Exit (F8): Exits Configuration mode.


    Question: What is the size of 2711P-K10C15A1 Membrane Keyboard?

    Answer: The 2711P-K10C15A1 keypad is 10.4-inch.


    Question: What is the 2711P-K10C15A1 Panelview Plus 1000 HMI parts price?

    Answer: Submit a fast quote, send VICPAS an email for best price.


    Common misspellings: 

    2711P-K1oC15A1
    2711P-K10Cl5A1
    2711P-K10C15Al
    711P-K10C15A1
    271P-K10C15A1
    2711-K10C15A1
    2711PK10C15A1
    27l1P-K10C15A1
    271lP-K10C15A1
    2711P-Kl0C15A1

    Review
    • Loading...
    Please send your message to us
    *Email
    Tel
    *Title
    *Content
    Upload
    • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
    Do you want to quickly know the product quotation you need?
    • Fast Quote
    • Worldwide Shipping
    • 12 Months Warranty
    • Customize Service
    subscription
    KEEP IN TOUCH
    Please send your message to us
    *Email
    Tel
    *Title
    *Content
    Upload
    • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
    CONTACT US
    QR code
    Mobile Web