PP882 3BSE069275R1 Front Overlay HMI Panel Glass
HMI Panel 800 PP882 3BSE069275R1 Touch Screen Panel Front Overlay Repair Replacement
Order each part separately is available
VICPAS supply HMI Panel 800 PP882 3BSE069275R1 Touch Digitizer Glass and Protective Film with 365 Days warranty and support Urgent Worldwide Shipping.
Panel 800 is a user-friendly, intuitive and ergonomic operator panel that combines slim, space-saving dimensions with a comprehensive range of advanced functions. PP882 3BSE069275R1 Protective Film Touch Screen Panel 800 family comprises user-friendly, intuitive and ergonomic operator panels that combine slim, space-saving dimensions with a comprehensive range of advanced functions. Adding to the already well-established feature-rich Panel 800 version 6.2 our new Rugged and Black panels are designed to perform in challenging harsh environments. Whether it is heavy outdoor use, usage in areas with explosion risk, or ship bridge use in marine applications, they are ready to provide you with the information needed.
Designed to make process automation easy, PP882 3BSE069275R1 Front Overlay Touch Membrane panels are equipped with advanced process and equipment control functionality, maneuvered by touching the LCD display. With market-leading performance and stunning graphical ability, Panel 800 erodes the line between ordinary Operator Panels and PC- based HMIs. Panels are configured using Panel Builder tool which contains a wide range of advanced functions. The functions are tested and developed with customer needs and preferences in focus.
Specifications:
The table below describes the parameters of the PP882 3BSE069275R1 Protective Film Touch Digitizer Glass HMI Panel 800.
Part Number: | PP882 3BSE069275R1 |
Touch Material: | Polyester on glass |
Active Area Of Display: | 261.12 × 163.2 mm |
Backlight: | LED |
Display Type: | TFT Color LCD |
Backlight Lifetime: | 50,000 hours |
Display Resolution: | 1280 × 800 pixels |
Operating Temperature: | -10 °C to +60 °C |
Storage Temperature: | -20 °C to +70 °C |
Warranty: | 365 Days |
Related HMI Panel 800 Terminals Part No. :
HMI Panel 800 | Description | Inventory status |
PP874 3BSE069271R2 | HMI Panel 800 PP874 Front Overlay Touch Membrane | In Stock |
PP874K 3BSE069273R1 | HMI Panel 800 Series PP874K Membrane Keypad Replacement Repair | In Stock |
PP874M 3BSE069279R1 | HMI Panel 800 Series PP874M Touch Digitizer Glass Overlay Repair | Available Now |
PP875 3BSE092977R1 | HMI Panel 800 PP875 HMI Panel Glass Protective Film Replacement | Available Now |
PP875H 3BSE092983R1 | HMI Panel 800 Series PP875H Touch Screen Monitor Front Overlay | In Stock |
PP875M 3BSE092982R1 | HMI Panel 800 Series PP875M Front Overlay MMI Touch Screen | In Stock |
PP877 3BSE069272R1 | HMI Panel 800 Series PP877 HMI Touch Screen Protective Film | Available Now |
PP877 3BSE069272R2 | HMI Panel 800 Series PP877 Protective Film Touchscreen Repair | In Stock |
PP877K 3BSE069274R1 | HMI Panel 800 Series PP877K HMI Membrane Switch Touch Screen Glass | Available Now |
PP880R 3BSE069295R1 | HMI Panel 800 Series PP880R Front Overlay Touch Screen Panel Repair | In Stock |
PP881 3BSE092978R1 | HMI Panel 800 Series PP881 Touch Screen Protective Film Replacement | In Stock |
PP882 3BSE069275R1 | Panel 800 Series PP882 Front Overlay Touch Digitizer Glass | Available Now |
PP883 3BSE092979R1 | Panel 800 PP883 Protective Film HMI Panel Glass Replacement | In Stock |
Panel 800 Repair | Description | Inventory status |
Panel 800 HMI Manuals PDF Download:
FAQ:
Question: Installation Process
Solution: The following is needed:
• ATorxTX7screwdriver
1. Unpack and check the delivery. If damage is found, notify the supplier.
2. Place the operator panel on a stable surface during installation. Dropping the operator panel or letting it fall may cause damage.
3. To cut a correct opening for the operator panel, use the cut out dimensions in the outline drawing.
4. Secure the operator panel in position by screwing the M4 Torx screw, allowing the built-in bracket to tighten against the panel:
5. Connect the cables in the specified order, according to the drawing and steps below.
• The operator panel must be brought to ambient temperature before it is started up. If condensation forms, ensure that the operator panel is dry before connecting it to the power outlet.
• Ensure that the operator panel and the controller system have the same electrical grounding (reference voltage level), otherwise errors in communication may occur.
• Ensure that the voltage and polarity of the power source is correct.
• Separate high voltage cables from signal and supply cables.
• Shielded communication cables are recommended.
– Connect cable A.
– Connect cable B, using an M5 screw and a grounding conductor (as short as possible), that is sized correctly according to local electrical codes.
– Connect cable C.
– Connect cable D. The recommended cross-section of the cable is 1.5 mm2..
6. Carefully remove the protective film over the operator panel display, take care to avoid static electricity that could damage the panel.