ESA Text HMI VT440 VT4401SF0P0 Membrane Keyboard Replacement
ESA Text HMI VT440 VT4401SF0P0 Membrane Keyboard Replacement
ESA TEXT HMI VT440 VT4401SF0P0 Membrane Keyboard Replacement
VT440 1SF0P0 ESA VIDEO TERMINAL (VT) is a device that allows the user to control orsimply monitor a productive process. It can send commands using configuredby the user; it can send data determining the process on hand andcan display information deriving from the productive process. The informationcan be in the form of an Alarm, an Information (Info-) Message or inbinary data format.
VICPAS supply ESA TEXT HMI VT440 membrane switch with 6 months warranty and support Urgent Worldwide Shipping.
Specifications:
The table below describes the parameters of the ESA VT4401SF0P0 HMI Parts.
Brand: | ESA |
Display Type: | Graphic LCD 16 colors STN |
Resolution: | 320x240 |
Warranty: | 6-Months Warranty |
Product Line: | VT TEXT |
Display Type: | TEXT LCD |
Display area size: | 4.55x3.43 |
Columns by Rows: | Depending on used Font |
Size: | 5.7" |
Part Number: | VT4401SF0P0 |
Related ESA VT440 Part No. :
ESA VT440 | Description | Inventory status |
VT4401SF0P0 | ESA Text HMI VT440 VT4401SF0P0 Membrane Keyboard Replacement | In Stock |
VT4402SF000 | ESA Text HMI VT440 VT4402SF000 Membrane Switch Replacement | In Stock |
VT440L1SF000 | ESA Text HMI VT440 VT440L1SF000 Membrane Keypad Repair Replacement | In Stock |
ESA VT TEXT | Description | Inventory status |
ESA VT440 Operator Panel HMI Manuals PDF Download:
FAQ:
Question: How to adjust the contrast on the ESA VT440 Display?
Answer:To improve the quality of the representation on the display it may be necessaryto adjust its contrast. This can be done by rotating the trimmer (C) atthe back of the VT ; turn it (using a small screwdriveror a trimmer tool) in one direction and, if the display quality worsens,turn it the other way.
Question: What is the VT440 Termination of CAN line?
Answer:The VT in question integratesthe termination resistances of the serial line (typically 120 ohms)which can be inserted by means of a jumper (preset on 1-2, line not terminated).To activate the termination:
• Make sure the device is not connected to the power supply.
• Remove the cover.
• Identify the jumper unit J2.
• Position the jumper between pins 2 and 3 (line terminated).
• Replace the back cover.